Explore ›
Finding
Finding
adverse
Vaginal mesh augmentation carried a 5.9% 5-year risk of surgery for mesh complications (vs 0.7% in native tissue, p<0.0001; adjusted HR 8.21, 95%CI 6.31-10.67), with the risk increasing over calendar years from 2.6% in 2005 to 4.8% in 2008 at 2-year follow-up.
| Effect size | HR 8.21 |
| CI | 95%CI 6.31, 10.67 |
| Follow-up | 5 years |
| Comparator | Native tissue anterior colporrhaphy (without mesh) |
| Effect summary | adverse; HR 8.21; CI: 95%CI 6.31, 10.67 |
| Adverse events | mesh complications 5.9% (5-year risk), 2.6% (2005), 4.8% (2008) |
Connected entities
Interventions
Conditions
Populations
Source
PMC3894057
Long-term outcomes of vaginal mesh versus native tissue repair for anterior vaginal wall prolapse